IVET 4.5

High-output E-core isolation transformer without casing, for self installation. The product is multi tap, meaning you can handle 120/230/240 V going in and out.

Mastervolt recommends to install the IVET heavy-duty isolation transformer with Soft Start. Soft Start suppresses the inrush current from the transformer and prevents the power fuse from blowing.

Product code: 85000450
download pdf

Specifications

General specifications
Output voltage (± 5%) 120/220/240 V
Output frequency range 45-65 Hz
Input voltage range 110/220/240 V
Nominal input current (230 V) 20 A
Input frequency range 45-65 Hz
Efficiency > 93 %
Power 4500 W
Dimensions, hxwxd 330 x 240 x 185 mm
13.0 x 9.4 x 7.3 inch
Weight 35 kg
77.2 lb
 
Technical specifications
Technology E-core
Earth leakage switch no
No-load power consumption < 10 W W
Temperature range (ambient temp.) 0 °C to 40 °C, derating power > 40 °C
32 to 104 °F
Relative humidity max. 95%
Protection degree IP00
Cooling natural cooling
Soft start no
MasterBus compatible no
 
 